NSN 5985-00-126-4391

Part Details | ELECTRICAL DUMMY LOAD

5985-00-126-4391 A specific electrical element or set of electrical elements that are connected together to form a fixed arrangement and used as a substitute load for terminating an electrical circuit. A dummy load contains all the essential electrical characteristics necessary to terminate the circuit but does not function in the same manner as the load which it replaces. Examples are resistors used to replace antennas, batteries, loudspeakers, or the like. Includes single port terminations of twin lead, coaxial and waveguide transmission lines as low power terminations of a section of a transmission system in a specified manner. Includes dummy loads when arranged in a group or bank. Excludes power absorbers. See also LOAD BANK, ELECTRICAL.

Alternate Parts: 200505, 200-505, FT1000, 5985-00-126-4391, 00-126-4391, 5985001264391, 001264391

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 06, 197300-126-439100335 ( DUMMY LOAD, ELECTRICAL )
REFERENCE DRAWINGS & PICTURES

COAXIAL MOUNTED

Cross Reference | NSN 5985-00-126-4391
Part Number Cage Code Manufacturer
200-50523042TRILITHIC, INC.
FT100023042TRILITHIC, INC.
Technical Data | NSN 5985-00-126-4391
Characteristic Specifications
STYLE DESIGNATOR COAXIAL MOUNTED
OVERALL LENGTH1.938 INCHES NOMINAL
OVERALL DIAMETER0.562 INCHES NOMINAL
FREQUENCY RANGE RATING+0.000 TO +1.000 MEGAHERTZ
POWER RATING1.000 WATTS AVERAGE
IMPEDANCE RATING IN OHMS1000.0 NOMINAL
VOLTAGE STANDING WAVE RATIO1.50
VOLTAGE STANDING WAVE RATIO FREQUENCY RANGE+0.000 TO +1.000 MEGAHERTZ
TERMINATION TYPE CONNECTION COAXIAL
COAXIAL CONNECTOR SERIES DESIGNATION SMA
CONNECTOR END DESIGN FEMALE AND MALE
COOLING METHOD SELF-COOLED
OPERATING POSITION ALL POSITIONS