Part Details | ELECTRICAL RESOLVER
5990-01-012-8062 An item consisting of a rotor and a stator inductively coupled. It usually has two rotor windings displaced from each other by 90 degrees and two stator windings similarly displaced. The output voltage(s) is a trigonometric function of the input voltage(s) and the angular displacement of the rotor with respect to the stator. See also SYNCHRO (as modified) and GONIOMETER, ELECTRICAL. Excludes TRANSOLVER, ELECTRICAL and potentiometer sine/cosine electrical resolvers.
Alternate Parts: 11R40N4R8A, MILR215304, MIL-R-21530/4, 5990-01-012-8062, 01-012-8062, 5990010128062, 010128062
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | NOV 18, 1975 | 01-012-8062 | 22966 ( RESOLVER, ELECTRICAL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5990-01-012-8062
Part Number | Cage Code | Manufacturer |
---|---|---|
11R40N4R8A | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
MIL-R-21530/4 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 5990-01-012-8062
Characteristic | Specifications |
---|---|
BODY SIZE | 11 |
STATOR INPUT VOLTAGE RATING IN VOLTS | 115.0 NOMINAL |
STATOR INPUT CURRENT RATING | 29.0 MILLIAMPERES NOMINAL |
STATOR INPUT ELECTRICAL POWER RATING | 500.0 MILLIWATTS NOMINAL |
FREQUENCY IN HERTZ | 400.0 MINIMUM AND 800.0 MAXIMUM |
TRANSFORMATION RATIO EQUALITY IN PERCENT | 1.0 NOMINAL |
PHASE SHIFT ANGLE IN DEG | 2.400 INPUT TO OUTPUT NOMINAL |
MAXIMUM TEMP RISE | 20.0 DEG CELSIUS |
MAXIMUM FUNDAMENTAL NULL VOLTAGE IN MILLIVOLTS PER VOLT | 120.00 OUTPUT |
ELECTRICAL ERROR ANGULAR RANGE IN MINUTES | M0.333/P0.333 |
ACTUATOR FRICTION TORQUE AT MINUS 55 DEG CELSIUS | 25.0 CENTIMETER-GRAMS MAXIMUM |
TEST DATA DOCUMENT | 81349-MIL-R-21530 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTING GENERAL TYPE DATA ON CERTAIN ENVIRONMENTAL AND PERFORMANCE REQUIREMENTS AND TEST CONDITIONS THAT ARE SHOWN AS "TYPICAL", "AVERAGE", "NOMINAL", ETC.). |