NSN 5999-00-167-1122
Part Details | DELAY LINE
5999-00-167-1122 An item which provides a predetermined delay to an electrical pulse, while maintaining substantially the same waveform. The delay is obtained by means of a real or artificial transmission line or equivalent device. The equivalent device may be acoustic, distributive, lumped constant, magnetic solid state, or surface acoustical wave type. See also ATTENUATOR, (as modified); TRANSFORMER, (as modified); and OSCILLATOR, PULSE DELAY.
Alternate Parts: 13A32B, X12020500, X-120-20-500, 2679036, 5999-00-167-1122, 00-167-1122, 5999001671122, 001671122
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | NOV 20, 1971 | 00-167-1122 | 06373 ( DELAY LINE ) |
REFERENCE DRAWINGS & PICTURES
CAPSULE, DIVIDED

FOUR POSITION RECTANGULAR

Cross Reference | NSN 5999-00-167-1122
Part Number | Cage Code | Manufacturer |
---|---|---|
13A32B | 00222 | ESC CONTROL ELECTRONICS LLCDBA CONTROL ELECTRONICS DIVISION OF |
X-120-20-500 | 03947 | MICRO NETWORKS CORPORATION |
2679036 | 10001 | NAVAIR AND NAVSEA MANAGEDORIGINAL DESIGN ACTIVITY DWG NOT |
Technical Data | NSN 5999-00-167-1122
Characteristic | Specifications |
---|---|
SIGNAL DELAY METHOD | INDUCTANCE |
DELAY TIME VARIATION METHOD | VARIABLE |
INDIVIDUAL SECTION QUANTITY | 1 |
SECTION DELAY TIME | CN120.000 NANOSECONDS NOMINAL |
OPERATING TEMP RANGE | -0.0 TO +75.0 DEG CELSIUS |
ATTENUATION IN DECIBELS | 0.500 |
VOLTAGE RATING | 200.000 VOLTS NOMINAL |
PULSE RISE TIME RATING | 5.0 NANOSECONDS |
BODY STYLE | CAPSULE, DIVIDED |
BODY LENGTH | 2.000 INCHES NOMINAL |
BODY WIDTH | 0.500 INCHES MAXIMUM |
BODY DEPTH | 0.750 INCHES MAXIMUM |
MATERIAL AND LOCATION | PLASTIC, DIALLYL PHTHALATE, MIL-M-14, TYPE SDG OVERALL |
SURFACE TREATMENT AND LOCATION | ENAMEL, TT-E-516 OVERALL |
TERMINAL TYPE AND QUANTITY | 4 WIRE LEADS |
MOUNTING FACILITY | TERMINAL |
MOUNTING FACILITY QUANTITY | 4 |
MOUNTING PROVISION ARRANGEMENT STYLE | FOUR POSITION RECTANGULAR |
LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 0.500 INCHES NOMINAL |
LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.600 INCHES NOMINAL |