5999-00-504-9449 A resistive element which dissipates sufficient heat to melt the fusible material or distort the bimetallic element of an overload protective device when the temperature, as a result of an overload in an electrical circuit, reaches a predetermined value. Excludes COIL (as modified); RESISTANCE ELEMENT; RESISTOR,THERMAL; THERMAL RELEASE,CIRCUIT BREAKER; and items with integral bimetallic element, contacts, or fusible material.

Alternate Parts: LO6000, 9104H3950A, 9104H3950, 29104H3950, H3950, 9104H3950, 9104-H-3950, 51490118, 514901-18, 59995049449, 5999-00-504-9449, 00-504-9449, 5999005049449, 005049449

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JAN 01, 196100-504-944960584 ( HEATER, THERMAL RELEASE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5999-00-504-9449
Part Number Cage Code Manufacturer
LO600016236DLA LAND AND MARITIMEDBA ENGINEERING AND TECHNICAL
9104H3950A27192DRS POWER & CONTROL TECHNOLOGIES,INC
9104H395027192DRS POWER & CONTROL TECHNOLOGIES,INC
29104H395027192DRS POWER & CONTROL TECHNOLOGIES,INC
H395027192DRS POWER & CONTROL TECHNOLOGIES,INC
9104-H-395015605EATON CORPOPNS & TECHNICAL CENTER
514901-1880020NAVAL AIR WARFARE CENTER AIRCRAFTDIVISION CODE 4.8.8.0.0.B BLDG 148-2
5999504944921877NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NAVAL AND MARINE SYSTEMS
Technical Data | NSN 5999-00-504-9449
Characteristic Specifications
CURRENT RATING FOR WHICH DESIGNED12.2 AMPERES MINIMUM AND 13.0 AMPERES MAXIMUM
MOUNTING FACILITY TYPE AND QUANTITY2 UNTHREADED HOLE
OVERALL LENGTH1.710 INCHES NOMINAL
OVERALL HEIGHT1.188 INCHES NOMINAL
OVERALL WIDTH1.000 INCHES NOMINAL
SPECIAL FEATURESITEM MUST COMPLY WITH REQUIREMENTS OF DEFENSE SUPPLY CENTER COLUMBUS PRODUCTION STANDARD NO. LO6000
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICSREFERENCE NUMBER DIFFERENTIATING MATERIAL WILL BE IN ACCORDANCE WITH NAVAL INVENTORY CONTROL POINT ACTIVITY HX QUALITY CONTROL; MANUFACTURING AND TESTING SPECIFICATIONS AVAILABLE AT THE DLA ICP
CRITICALITY CODE JUSTIFICATIONZZZY