NSN 6105-00-055-1957
Part Details | CONTROL MOTOR
6105-00-055-1957 A motor which is designed to be operated from two independent voltage sources, in such a way that variations in one voltage source will determine the direction and speed of the motor. In the alternating current type the voltages are usually applied to a split-phase stator, whereas in the direct current type, one voltage is applied to the stator and the other to the armature. Low inertia and rapid reversibility are inherent characteristics of this type of motor. See also SERVOMOTOR, AUTOMATIC PILOT.
Alternate Parts: 8M300C2, 6105-00-055-1957, 00-055-1957, 6105000551957, 000551957
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | JUN 01, 1967 | 00-055-1957 | 19258 ( MOTOR, CONTROL ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6105-00-055-1957
Part Number | Cage Code | Manufacturer |
---|---|---|
8M300C2 | 06989 | API HAROWE INCDBA API MOTION DIV API |
Technical Data | NSN 6105-00-055-1957
Characteristic | Specifications |
---|---|
OVERALL LENGTH | 1.024 INCHES |
OVERALL WIDTH | 0.750 INCHES |
OVERALL HEIGHT | 0.750 INCHES |
MOUNTING METHOD | CLAMP RING |
MOUNTING FACILITY TYPE AND QUANTITY | 1 CLAMP COLLAR |
INCLOSURE FEATURE | TOTALLY INCLOSED |
INCLOSURE SPECIFICATION | COMMERCIAL |
CURRENT RATING METHOD | LOCKED ROTOR |
TORQUE RATING AND TYPE | 0.20 INCH-OUNCES STALLED |
TEMP RATING | 50.0 AMBIENT DEG CELSIUS AND -55.0 OPERATING DEG CELSIUS AND 125.0 OPERATING DEG CELSIUS |
COOLING METHOD | AMBIENT AIR |
TERMINAL TYPE AND QUANTITY | 6 WIRE LEAD |
CONTROL FIELD VOLTAGE TYPE AND RATING IN VOLTS | 35.0 AC |
CONTROL FIELD CURRENT RATING IN AMPS | 0.088 |
CONTROL FIELD IMPEDANCE RATING IN OHMS | 398.0 |
CONTROL FIELD WINDING TYPE | SINGLE WINDING W/CENTER TAP |
ROTOR SPEED RATING IN RPM | 6200.0 SINGLE NO LOAD |
FEATURES PROVIDED | HORIZONTAL MOUNTING POSITION AND VERTICAL MOUNTING POSITION |