NSN 6110-00-769-5393
Part Details | MOTOR CONTROLLER
6110-00-769-5393 A device which, in addition to starting and stopping a motor, performs one or more of the following functions: reverses the rotation, selects the speed, and/or regulates the speed of a motor. Includes items of this type whose design provides means for operation with a rheostat or speed regulator which may be integral or included. Items such as drum switches may be included. See also STARTER, MOTOR.
Alternate Parts: 6967ED106B2, 6967ED106A2, 6967ED106A2, MILC2212, 6110-00-769-5393, 00-769-5393, 6110007695393, 007695393
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | JAN 01, 1960 | 00-769-5393 | 00904 ( CONTROLLER, MOTOR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-00-769-5393
Part Number | Cage Code | Manufacturer |
---|---|---|
6967ED106B2 | 27192 | DRS POWER & CONTROL TECHNOLOGIES,INC |
6967ED106A2 | 27192 | DRS POWER & CONTROL TECHNOLOGIES,INC |
6967ED106A2 | 15605 | EATON CORPOPNS & TECHNICAL CENTER |
MILC2212 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 6110-00-769-5393
Characteristic | Specifications |
---|---|
OPERATING VOLTAGE CHARACTERISTIC | FULL |
AC VOLTAGE RATING | 440.000 VOLTS NOMINAL |
FREQUENCY RATING | 60.000 HERTZ NOMINAL |
PHASE | THREE |
HORSEPOWER RATING | 10.000 |
FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
FUSE ACCOMMODATION QUANTITY | 2 |
CONTROL TYPE | LOCAL |
ACTUATION METHOD | MAGNETIC |
ACTUATOR VOLTAGE | 440.0 AC |
FREQUENCY IN HERTZ | 60.0 |
PERFORMANCE TYPE | SEMIAUTOMATIC |
LOAD PROTECTION TYPE | OVERLOAD AND UNDERVOLTAGE |
DUTY CYCLE | CONTINUOUS |
AMBIENT TEMP | 50.000 DEG CELSIUS |
SPEED ADJUSTMENTS | TWO SPEED |
INCLOSURE FEATURE | DRIPPROOF |
OVERALL WIDTH | 9.500 INCHES NOMINAL |
OVERALL LENGTH | 16.000 INCHES NOMINAL |
OVERALL HEIGHT | 20.100 INCHES NOMINAL |
MOUNTING CONFIGURATION | FOUR 17/32 IN. DIA MTG HOLES ON 18 IN. BY 12-1/2 IN. MTG CENTERS |
SWITCH FUNCTIONAL POSITIONS | SLOW AND MANUAL AND AUTOMATIC AND START EMERGENCY RUN AND STOP AND RESET AND EMERGENCY RUN AND RESET |
NONDEFINITIVE SPEC/STD DATA | 1 SIZE |