NSN 6110-01-068-3201
Part Details | VOLTAGE REGULATOR
6110-01-068-3201 A component within a single inclosure or provided with a single mounting specifically designed to control automatically the voltage output of an electrical system within certain required limits, regardless of variations of the effective load or of input voltages within a specific range. Does not include items in which regulation is accomplished solely by transformer action. See also REGULATOR SET, VOLTAGE. Excludes REGULATOR, ENGINE GENERATOR.
Alternate Parts: IES9101B, 6110-01-068-3201, 01-068-3201, 6110010683201, 010683201
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | NOV 21, 1978 | 01-068-3201 | 00176 ( REGULATOR, VOLTAGE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-01-068-3201
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| IES9101B | 58474 | SUPERIOR ELECTRIC HOLDING GROUP LLCDBA SUPERIOR ELECTRIC |
Technical Data | NSN 6110-01-068-3201
| Characteristic | Specifications |
|---|---|
| REGULATION METHOD | ELECTRONIC |
| ELECTRONIC DEVICE TYPE | SOLID STATE |
| CIRCUIT TYPE | PARALLEL |
| COMPENSATION PROVIDED | INDIVIDUAL DROOP |
| INPUT CURRENT TYPE | AC |
| INPUT VOLTAGE RATING IN VOLTS | 95.0 MINIMUM AND 135.0 MAXIMUM |
| INPUT FREQUENCY RATING IN HERTZ | 45.0 MINIMUM AND 66.0 MAXIMUM |
| INPUT PHASE | SINGLE |
| OUTPUT CURRENT TYPE | AC |
| OUTPUT VOLTAGE RATING IN VOLTS | 110.0 MINIMUM AND 120.0 MAXIMUM |
| OUTPUT CURRENT RATING | 8.7 AMPERES MAXIMUM |
| RECOVERY TIME | 0.03 SECONDS |
| OPERATING TEMP RANGE | -20.0 TO +50.0 DEG CELSIUS |
| INCLOSURE FEATURE | INCLOSED, VENTILATED INCLOSURE |
| OVERALL WIDTH | 14.875 INCHES NOMINAL |
| OVERALL LENGTH | 19.000 INCHES NOMINAL |
| OVERALL HEIGHT | 5.375 INCHES MAXIMUM |
| MOUNTING METHOD | F$DACU |