NSN 6110-01-128-4672
Part Details | ELECTRICAL MOTOR THERMAL-OVERLOAD PROTECTOR
6110-01-128-4672 A protective device specifically designed to prevent damage to an electrical motor due to failure of the motor to start, severe overloading of short duration, too frequent starting, high ambient temperature, high or low circuit voltages, failure of ventilation or any combination thereof. It is designed to be either automatically or manually reset. Excludes CIRCUIT BREAKEY; SWITCH (1), THERMOSTATIC; HEATER, THERMAL RELEASE; and RELAY (1), THERMAL.
Alternate Parts: MYJ32K0, MYJ32K0, 6110-01-128-4672, 01-128-4672, 6110011284672, 011284672
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | MAR 21, 1982 | 01-128-4672 | 60869 ( PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-01-128-4672
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| MYJ32K0 | 04320 | CURTISS-WRIGHT CONTROLS INTEGRATEDSENSING, INC. |
| MYJ32K0 | 82647 | SENSATA TECHNOLOGIES, INCDIV SENSATA ATTLEBORO |
Technical Data | NSN 6110-01-128-4672
| Characteristic | Specifications |
|---|---|
| OVERALL LENGTH | 1.531 INCHES NOMINAL |
| OVERALL DIAMETER | 1.031 INCHES NOMINAL |
| SPECIAL FEATURES | SIX SOLDER LUG TERM.;AUTOMATIC RESET;220 V 37 AMP MAX;440 V 28 AMP MAX;0.125 HP TO 1.5 HP MTR SIZE;32 SIZE HEATER;150 DEG C TEMP OPEN;102 DEG C TEMP CLOSE; |