NSN 6110-01-144-2621
Part Details | MAGNETIC CONTACTOR
6110-01-144-2621 An item consisting of contacts, a magnetic core, and a coil with or without inclosure which is used to repeatedly establish and break a circuit. The item does not provide overload protection and is not used in line to control any other electrical controls. Excludes RELAY, ELECTROMAGNETIC and STARTER, MOTOR.l circuit. Exludes RELAY, ELECTRO-MAGNETIC and STARTER, MOTOR.
Alternate Parts: RP900K4665XX6B30, 6110-01-144-2621, 01-144-2621, 6110011442621, 011442621
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | DEC 16, 1982 | 01-144-2621 | 31517 ( CONTACTOR, MAGNETIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-01-144-2621
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| RP900K4665XX6B30 | 73905 | JENNINGS TECHNOLOGY COMPANY LLCDBA JENNINGS |
Technical Data | NSN 6110-01-144-2621
| Characteristic | Specifications |
|---|---|
| NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | NOT DESIGNED PER NEMA STD |
| OPERATING VOLTAGE CHARACTERISTIC | FULL |
| DC VOLTAGE RATING | 50.0 KILOVOLTS NOMINAL |
| DIRECT CURRENT RATING IN AMPS | 300.0 |
| FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
| ACTUATION METHOD | MAGNETIC |
| DUTY CYCLE | CONTINUOUS |
| AMBIENT TEMP | -46.0 DEG CELSIUS AND 78.0 DEG CELSIUS |
| INCLOSURE FEATURE | FULLY INCLOSED |
| OVERALL WIDTH | 5.370 INCHES NOMINAL |
| OVERALL LENGTH | 5.110 INCHES MINIMUM AND 5.140 INCHES MAXIMUM |
| OVERALL HEIGHT | 13.495 INCHES MINIMUM AND 13.745 INCHES MAXIMUM |
| MOUNTING CONFIGURATION | FOUR 0.281 IN. DIA MTG HOLES ON 5.110 MIN,5.140 MAX IN. BY 4.610 MIN,4.640 MAX IN. MTG CTRS |