NSN 6110-01-147-0655
Part Details | MOTOR STARTER
6110-01-147-0655 A device primarily designed to control the supply circuit(s) of a motor in order to accelerate the motor from rest to normal speed. Includes manual starters with overload protection and manual, automatic or semiautomatic starters consisting of combinations of items such as relays, resistors, switches, circuit breakers, and the like. Excludes RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (as modified) and RELAY (as modified). For devices, which in addition to starting and stopping, reverse, select and/or regulate the speed of a motor, see CONTROLLER (as modified).
Alternate Parts: 202B5045G1S2, 6110-01-147-0655, 01-147-0655, 6110011470655, 011470655
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | FEB 10, 1983 | 01-147-0655 | 00905 ( STARTER, MOTOR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-01-147-0655
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 202B5045G1S2 | 02989 | GENERAL ELECTRIC COGE DRIVE SYSTEMS |
Technical Data | NSN 6110-01-147-0655
| Characteristic | Specifications |
|---|---|
| NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
| SIZE DESIGNATOR | 0 |
| OPERATING VOLTAGE CHARACTERISTIC | FULL |
| AC VOLTAGE RATING | 440.0 VOLTS NOMINAL |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| PHASE | THREE |
| AMP SIZE RATING | 18.0 |
| HORSEPOWER RATING | 0.500 |
| FEATURES PROVIDED | CIRCUIT PROTECTION FUSE AND ACCESSORY LOCATION INTERNAL |
| FUSE ACCOMMODATION QUANTITY | 2 |
| FUSE CURRENT RATING IN AMPS | 10.0 |
| CONTROL TYPE | LOCAL |
| ACTUATION METHOD | MAGNETIC |
| ACTUATOR VOLTAGE | 440.0 AC |
| FREQUENCY IN HERTZ | 60.0 |
| PERFORMANCE TYPE | AUTOMATIC AND MANUAL |
| LOAD PROTECTION TYPE | OVERLOAD AND UNDERVOLTAGE |
| DUTY CYCLE | CONTINUOUS |
| AMBIENT TEMP | 50.0 DEG CELSIUS |
| SPEED ADJUSTMENTS | 0 TO FULL SPEED |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DRIPPROOF |
| INCLOSURE FEATURE | DRIPPROOF |
| OVERALL WIDTH | 7.750 INCHES NOMINAL |
| OVERALL LENGTH | 22.125 INCHES NOMINAL |
| OVERALL HEIGHT | 7.375 INCHES NOMINAL |
| MOUNTING CONFIGURATION | SIX 15/32 IN. DIA HOLES ARRANGED IN TWO PARALLEL ROWS OF 3 EA; 5-3/4 IN. SPACING BETWEEN ROWS; 9-1/4 IN. CENTER TO CENTER SPACING FOR HOLES |
| SWITCH FUNCTIONAL POSITIONS | RESET AND START AND STOP |
| SPECIAL FEATURES | REMOTE MASTER CONTROL W/START AND STOP SWITCH POSITIONS NOT SUPPLIED WITH UNIT;ACCESSORY CONTROL POWER TRANSFORMER RATED 440 V PRIMARY 115 V SECONDARY; 250VA; FUSED TWO 6 AMP FUSES |