6110-01-148-4696 A device primarily designed to control the supply circuit(s) of a motor in order to accelerate the motor from rest to normal speed. Includes manual starters with overload protection and manual, automatic or semiautomatic starters consisting of combinations of items such as relays, resistors, switches, circuit breakers, and the like. Excludes RELAY-SWITCH; CIRCUIT BREAKER; SWITCH (as modified) and RELAY (as modified). For devices, which in addition to starting and stopping, reverse, select and/or regulate the speed of a motor, see CONTROLLER (as modified).

Alternate Parts: 6962ED2537A, 6962CD4859, MILC2212, MIL-C-2212, 6110-01-148-4696, 01-148-4696, 6110011484696, 011484696

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
61MAR 06, 198301-148-469600905 ( STARTER, MOTOR )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-01-148-4696
Part Number Cage Code Manufacturer
6962ED2537A27192DRS POWER & CONTROL TECHNOLOGIES,INC
6962CD485927192DRS POWER & CONTROL TECHNOLOGIES,INC
MIL-C-221281349MILITARY SPECIFICATIONSPROMULGATED BY MILITARY
Technical Data | NSN 6110-01-148-4696
Characteristic Specifications
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN DESIGNED PER NEMA STD
SIZE DESIGNATOR4
OPERATING VOLTAGE CHARACTERISTIC FULL
AC VOLTAGE RATING440.0 VOLTS NOMINAL
FREQUENCY RATING60.0 HERTZ NOMINAL
PHASE THREE
HORSEPOWER RATING100.000
FEATURES PROVIDED CIRCUIT PROTECTION FUSE
FUSE ACCOMMODATION QUANTITY3
FUSE CURRENT RATING IN AMPS10.0
CONTROL TYPEK$DAAY
ACTUATION METHOD MAGNETIC
ACTUATOR VOLTAGE440.0 AC
FREQUENCY IN HERTZ60.0
PERFORMANCE TYPE AUTOMATIC AND MANUAL
LOAD PROTECTION TYPE OVERLOAD AND UNDERVOLTAGE
DUTY CYCLE CONTINUOUS
AMBIENT TEMP50.0 DEG CELSIUS
SPEED ADJUSTMENTS 0 TO FULL SPEED
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION DRIPPROOF
INCLOSURE FEATURE DRIPPROOF
OVERALL WIDTH18.109 INCHES NOMINAL
OVERALL LENGTH26.125 INCHES NOMINAL
OVERALL HEIGHT10.375 INCHES NOMINAL
MOUNTING CONFIGURATIONSIX 17/32 IN. DIA HOLES; RECTANGULAR ARRANGEMENT; 2 ROWS OF 3 EA SPACED 7-1/4 IN. CENTER TO CENTER; 24 IN. SPACING BETWEEN ROW CENTERLINES
SWITCH FUNCTIONAL POSITIONS EMERGENCY RUN AND OFF AND REMOTE AND RUN
SPECIAL FEATURESREMOTE SWITCH POSITION PROVIDES AUTOMATIC OR MANUAL CONTROL CAPABILITY FROM REMOTE CONSOLE ACCESSORY