NSN 6110-01-154-6939
Part Details | MAGNETIC CONTACTOR
6110-01-154-6939 An item consisting of contacts, a magnetic core, and a coil with or without inclosure which is used to repeatedly establish and break a circuit. The item does not provide overload protection and is not used in line to control any other electrical controls. Excludes RELAY, ELECTROMAGNETIC and STARTER, MOTOR.l circuit. Exludes RELAY, ELECTRO-MAGNETIC and STARTER, MOTOR.
Alternate Parts: 6957ED254A, 6957ED25-4A, MILC2212, MIL-C-2212, 6110-01-154-6939, 01-154-6939, 6110011546939, 011546939
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | MAY 29, 1983 | 01-154-6939 | 31517 ( CONTACTOR, MAGNETIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-01-154-6939
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 6957ED25-4A | 27192 | DRS POWER & CONTROL TECHNOLOGIES,INC |
| MIL-C-2212 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 6110-01-154-6939
| Characteristic | Specifications |
|---|---|
| NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
| OPERATING VOLTAGE CHARACTERISTIC | FULL |
| AC VOLTAGE RATING | 440.0 VOLTS NOMINAL |
| HORSEPOWER RATING | 10.000 |
| CONTROL TYPE | K$DAAY |
| ACTUATION METHOD | MAGNETIC |
| DUTY CYCLE | CONTINUOUS |
| AMBIENT TEMP | 50.0 DEG CELSIUS |
| INCLOSURE FEATURE | OPEN |