NSN 6110-01-159-2244
Part Details | MOTOR CONTROLLER
6110-01-159-2244 A device which, in addition to starting and stopping a motor, performs one or more of the following functions: reverses the rotation, selects the speed, and/or regulates the speed of a motor. Includes items of this type whose design provides means for operation with a rheostat or speed regulator which may be integral or included. Items such as drum switches may be included. See also STARTER, MOTOR.
Alternate Parts: 6962ED1402A2, 6962ED1402, MILC2212, MIL-C-2212, 6110-01-159-2244, 01-159-2244, 6110011592244, 011592244
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | AUG 04, 1983 | 01-159-2244 | 00904 ( CONTROLLER, MOTOR ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-01-159-2244
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 6962ED1402A2 | 27192 | DRS POWER & CONTROL TECHNOLOGIES,INC |
| 6962ED1402 | 27192 | DRS POWER & CONTROL TECHNOLOGIES,INC |
| MIL-C-2212 | 81349 | MILITARY SPECIFICATIONSPROMULGATED BY MILITARY |
Technical Data | NSN 6110-01-159-2244
| Characteristic | Specifications |
|---|---|
| NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
| SIZE DESIGNATOR | 2 |
| OPERATING VOLTAGE CHARACTERISTIC | FULL |
| AC VOLTAGE RATING | 440.0 VOLTS NOMINAL AND 110.0 VOLTS NOMINAL |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| PHASE | THREE |
| HORSEPOWER RATING | 25.000 |
| FEATURES PROVIDED | CIRCUIT PROTECTION FUSE |
| FUSE ACCOMMODATION QUANTITY | 4 |
| FUSE CURRENT RATING IN AMPS | 10.0 |
| CONTROL TYPE | LOCAL |
| ACTUATION METHOD | MANUAL |
| PERFORMANCE TYPE | MANUAL |
| DUTY CYCLE | CONTINUOUS |
| AMBIENT TEMP | 50.0 DEG CELSIUS |
| HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | DRIPPROOF |
| OVERALL WIDTH | 16.120 INCHES NOMINAL |
| OVERALL LENGTH | 18.120 INCHES NOMINAL |
| OVERALL HEIGHT | 8.060 INCHES NOMINAL |
| MOUNTING CONFIGURATION | FOUR 17/32 IN. DIA HOLES; RECTANGULAR PATTERN; ON 12-1/2 IN. BY 16-3/8 IN. CENTERS |
| SWITCH FUNCTIONAL POSITIONS | EMERGENCY RUN AND RESET AND REST AND RUN AND START AND START EMERGENCY RUN AND STOP |