NSN 6110-01-188-0385
Part Details | MAGNETIC CONTACTOR
6110-01-188-0385 An item consisting of contacts, a magnetic core, and a coil with or without inclosure which is used to repeatedly establish and break a circuit. The item does not provide overload protection and is not used in line to control any other electrical controls. Excludes RELAY, ELECTROMAGNETIC and STARTER, MOTOR.l circuit. Exludes RELAY, ELECTRO-MAGNETIC and STARTER, MOTOR.
Alternate Parts: 6942ED1643 PIECE 2, 6938ED3810A, 6938ED38-10A, 6110-01-188-0385, 01-188-0385, 6110011880385, 011880385
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | AUG 30, 1984 | 01-188-0385 | 31517 ( CONTACTOR, MAGNETIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6110-01-188-0385
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 6942ED1643 PIECE 2 | 27192 | DRS POWER & CONTROL TECHNOLOGIES,INC |
| 6938ED38-10A | 27192 | DRS POWER & CONTROL TECHNOLOGIES,INC |
Technical Data | NSN 6110-01-188-0385
| Characteristic | Specifications |
|---|---|
| NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION STANDARDS DESIGN | DESIGNED PER NEMA STD |
| OPERATING VOLTAGE CHARACTERISTIC | FULL |
| DC VOLTAGE RATING | 250.0 VOLTS NOMINAL |
| HORSEPOWER RATING | 30.000 |
| CONTROL TYPE | K$DAAY |
| ACTUATION METHOD | MAGNETIC |
| AMBIENT TEMP | 50.0 DEG CELSIUS |
| INCLOSURE FEATURE | OPEN |