NSN 6115-00-965-6561
Part Details | STEAM TURBINE GENERATOR SET
6115-00-965-6561 A generator set using a steam turbine as the prime mover.
Alternate Parts: LJ91000, LJ91000, 6115-00-965-6561, 00-965-6561, 6115009656561, 009656561
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
61 | JAN 01, 1962 | 00-965-6561 | 00478 ( GENERATOR SET, STEAM TURBINE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6115-00-965-6561
Part Number | Cage Code | Manufacturer |
---|---|---|
LJ91000 | 0BR59 | SIEMENS GOVERNMENT TECHNOLOGIES,INC. |
LJ91000 | 93235 | TURBODYNEDIV OF DRESSER INDUSTRIES INC |
Technical Data | NSN 6115-00-965-6561
Characteristic | Specifications |
---|---|
CURRENT TYPE | AC |
AC WATTAGE RATING | 1500.0 WATTS |
FREQUENCY RATING | 60.0 HERTZ NOMINAL |
PHASE | THREE |
LINE TO LINE VOLTAGE IN VOLTS | 450.0 |
POWER FACTOR IN PERCENT | 0.8 |
EXCITOR TYPE | SELF-EXCITED |
EXCITOR | NOT INCLUDED |
AMBIENT TEMP IN DEG CELSIUS | 50.0 |
TEMP RISE RATING IN DEG CELSIUS FOR CONTINUOUS OPERATION | 100.0 |
MANUFACTURER NAME | ELECTRIC MACHINERY CO |
PRIME MOVER MANUFACTURER NAME | WORTHINGTON CORP |
STEAM OPERATING PRESSURE | 1050.0 POUNDS PER SQUARE INCH GAGE |
STEAM TEMP RATING | 940.0 DEG FAHRENHEIT |
TURBINE DESIGN TYPE | IMPULSE |
EXHAUST TYPE | CONDENSING |
STAGE TYPE | MULTIPLE |
TURBINE TO GENERATOR COUPLING METHOD | GEAR TRAIN |
MOUNTING TYPE | BASE |
OVERALL LENGTH | 141.000 INCHES NOMINAL |
OVERALL WIDTH | 72.000 INCHES NOMINAL |
OVERALL HEIGHT | 154.750 INCHES NOMINAL |
ACCESSORY COMPONENT QUANTITY | 1 |
ACCESSORY CONTROLLING AGENCY | ELECTRIC MACHINERY MFG CO. |
ACCESSORY COMPONENT NAME | STATIC EXCITATION AND VOLTAGE REGULATION SYSTEM |