NSN 6130-00-473-2196
Part Details | METALLIC RECTIFIER ASSEMBLY
6130-00-473-2196 Two or more individual rectifiers having a common mounting or mounted on each other, or two or more individual rectifiers fabricated into a common inseparable body. Each rectifier must have individual ratings. For rectifiers with an overall circuit rating, see RECTIFIER, METALLIC. See also RECTIFIER SET, METALLIC.
Alternate Parts: DQ2, 6303843272PCSP3, 6303-843272PCSP3, 6303843272PCBM98, 6303-843272PCBM98, 55001421, 55001-42-1, 50017APCSP3, 50017APCBM98, 105241CPC1, 105-241CPC1, 6130-00-473-2196, 00-473-2196, 6130004732196, 004732196
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JAN 01, 1963 | 00-473-2196 | 20974 ( RECTIFIER ASSEMBLY, METALLIC ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6130-00-473-2196
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| DQ2 | 29367 | HORVI SIGNAL MFG CORP |
| 6303-843272PCSP3 | 80064 | NAVAL SHIP SYSTEMS COMMAND |
| 6303-843272PCBM98 | 80064 | NAVAL SHIP SYSTEMS COMMAND |
| 55001-42-1 | 63743 | WARD LEONARD CT LLC |
| 50017APCSP3 | 63743 | WARD LEONARD CT LLC |
| 50017APCBM98 | 63743 | WARD LEONARD CT LLC |
| 105-241CPC1 | 63743 | WARD LEONARD CT LLC |
Technical Data | NSN 6130-00-473-2196
| Characteristic | Specifications |
|---|---|
| RECTIFYING MATERIAL | SELENIUM |
| INDIVIDUAL CIRCUIT CONNECTION QUANTITY | 2 |
| CIRCUIT TYPE | J ANY ACCEPTABLE |
| PHASE | SINGLE |
| RECTIFICATION METHOD | X ANY ACCEPTABLE |
| RMS INPUT MAXIMUM VOLTAGE RATING | 22.0 VOLTS |
| MAXIMUM OUTPUT CURRENT RATING | 500.0 MILLIAMPERES |
| LOAD TYPE | C ANY ACCEPTABLE |
| DC OUTPUT MAXIMUM VOLTAGE RATING | VAB12.0 VOLTS |
| OPERATING AMBIENT TEMP RANGE | +0.0 TO +50.0 DEG CELSIUS |
| OVERALL LENGTH | 3.687 INCHES NOMINAL |
| OVERALL WIDTH | 1.500 INCHES NOMINAL |
| OVERALL HEIGHT | 1.500 INCHES NOMINAL |
| MOUNTING METHOD | STUD |
| MOUNTING CONFIGURATION | ONE 10-32 THD AXIAL STUD EXTENDING 1 IN. EA END |
| TERMINAL QUANTITY | 8 |
| TERMINAL TYPE | SOLDER LUG |
| GROUNDING PROVISION | NOT INCLUDED |