NSN 6130-00-669-6659
Part Details | BATTERY CHARGER
6130-00-669-6659 A device consisting of one or more components utilizing an alternating or direct current source to reactivate batteries in which reversible chemical reactions occur. Use only for devices containing resistors, metallic, or electronic type rectifiers or vibrators and which are specifically designed for the purpose of charging batteries. May include filters, meters, load contactor and alarm circuits. May include battery charging switchboards which are supplied with integral or external means of rectification.
Alternate Parts: PD238A, FBC20, FBC25, FBC-25, PP1660G, SMD884022, SM-D-884022, 6130-00-669-6659, 00-669-6659, 6130006696659, 006696659
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 61 | JAN 01, 1963 | 00-669-6659 | 00480 ( CHARGER, BATTERY ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6130-00-669-6659
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| PD238A | 81336 | CHIEF OF ENGINEERSDEPT OF ARMY |
| FBC20 | 82386 | JAIDINGER MFG. CO., INC.DBA JAICO PRODUCTS |
| FBC-25 | 82386 | JAIDINGER MFG. CO., INC.DBA JAICO PRODUCTS |
| PP1660G | 80058 | JOINT ELECTRONICS TYPE DESIGNATIONSYSTEM |
| SM-D-884022 | 80063 | US ARMY COMMUNICATIONS &ELECTRONICS MATERIEL READINESS |
Technical Data | NSN 6130-00-669-6659
| Characteristic | Specifications |
|---|---|
| CHARGER TYPE | METALLIC RECTIFIER |
| CHARGING VOLTAGE IN VOLTS | 6.0 MINIMUM AND 24.0 MAXIMUM |
| CHARGING CURRENT RATING IN AMPS | 10.000 NOMINAL |
| CHARGING REGULATION METHOD | CONTINUOUS |
| AC VOLTAGE RATING | 105.0 VOLTS MINIMUM AND 125.0 VOLTS MAXIMUM |
| FREQUENCY RATING | 60.0 HERTZ NOMINAL |
| PHASE | SINGLE |
| DC VOLTAGE RATING | 6.0 VOLTS MINIMUM AND 24.0 VOLTS MAXIMUM |
| INCLOSURE TYPE | CASE |
| INCLOSURE MATERIAL | METAL |
| OVERALL WIDTH | 9.000 INCHES NOMINAL |
| OVERALL HEIGHT | 17.000 INCHES NOMINAL |
| OVERALL DEPTH | 22.000 INCHES NOMINAL |
| SPECIAL FEATURES | THREE POSITION,LOW,MEDIUM,HIGH DELAYED CIRCUIT BREAKER ACTION TO PERMIT SURGE LOADS; AUTOMATIC SWITCHING FROM HIGH RATE TO LOW RATE |