NSN 6250-00-225-0517
Part Details | LAMP BALLAST
6250-00-225-0517 An item specifically designed for use with fluorescent or mercury vapor lamps and starters to provide a high starting voltage for striking the arc and to stabilize the operating impedance of the circuit in order to maintain the operating current at a steady value.
Alternate Parts: BB166, 6250-00-225-0517, 00-225-0517, 6250002250517, 002250517
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
62 | JAN 01, 1961 | 00-225-0517 | 05123 ( BALLAST, LAMP ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6250-00-225-0517
Part Number | Cage Code | Manufacturer |
---|---|---|
BB166 | 02767 | BARWOOD ELECTRONICS INC |
Technical Data | NSN 6250-00-225-0517
Characteristic | Specifications |
---|---|
TERMINAL TYPE | ANY ACCEPTABLE |
TERMINAL QUANTITY | 6 |
TERMINAL LOCATION AND QUANTITY | 6 TOP |
LAMP WATTAGE RATING IN WATTS | 8.0 |
LAMP ACCOMMODATION QUANTITY | 1 |
OVERALL LENGTH | 2.890 INCHES NOMINAL |
OVERALL WIDTH | 2.130 INCHES NOMINAL |
OVERALL HEIGHT | 2.340 INCHES NOMINAL |
CURRENT TYPE | AC |
FREQUENCY RATING | 400.0 HERTZ NOMINAL |
VOLTAGE RATING | 115.0 VOLTS NOMINAL |
CURRENT RATING IN AMPS | 0.540 |
STARTING CHARACTERISTIC | RAPID |
STARTER | NOT REQUIRED |
POWER FACTOR CHARACTERISTIC | H$L |
MOUNTING METHOD | HOLES |
MOUNTING HOLE QUANTITY | 2 |
CENTER TO CENTER DISTANCE BETWEEN MOUNTING HOLES ALONG LENGTH | 2.510 INCHES |