NSN 6625-00-148-8097

Part Details | OSCILLOSCOPE

6625-00-148-8097 A test instrument which is designed to give visual indications on an LCD display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an LCD display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see INDICATOR (2) (as modified); MONITOR (as modified); and RECORDER (as modified). See also OSCILLOGRAPH.

Alternate Parts: 1062M0D116, 6625-00-148-8097, 00-148-8097, 6625001488097, 001488097

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66MAY 28, 197300-148-809700357 ( OSCILLOSCOPE )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-00-148-8097
Part Number Cage Code Manufacturer
1062M0D11630669E AND R ELECTRONICS INCDBA DUMONT OSCILLOSCOPE
Technical Data | NSN 6625-00-148-8097
Characteristic Specifications
SCREEN SIZE8 BY 10 CENTIMETERS
BEAM QUANTITY1
SWEEP CIRCUITS INCLUDED
GENERATOR DRIVEN FEATURE INCLUDED
SWEEP CIRCUIT TYPED ANY ACCEPTABLE AND F ANY ACCEPTABLE
SWEEP FREQUENCY RANGE+0.0 TO +4.0 HERTZ AND +0.0 TO +60.0 MEGAHERTZ
SINGLE TRIGGER SWEEP DURATION0.1 MICROSECONDS MINIMUM AND 1.0 MICROSECONDS MAXIMUM
AMPLIFIER DEFLECTION SENSITIVITY PROVISION NOT PROVIDED
INPUT INTENSITY MODULATION FEATURE NOT PROVIDED
AMPLITUDE CALIBRATING VOLTAGE WAVEFORM SQUARE WAVE
CALIBRATING PEAK TO PEAK AMPLITUDE1.0 VOLTS MINIMUM AND 3.0 VOLTS MAXIMUM
ACCURACY RANGE IN PERCENTM1.0/P1.0
CAMERA RECORDING DEVICE ACCOMMODATION NOT PROVIDED
CURRENT TYPE AC
VOLTAGE RATING115.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL
FREQUENCY RATING48.0 HERTZ NOMINAL AND 400.0 HERTZ NOMINAL
PHASEA$B
OVERALL LENGTH21.219 INCHES NOMINAL
OVERALL WIDTH8.250 INCHES NOMINAL
OVERALL HEIGHT11.500 INCHES NOMINAL
MOUNTING METHOD CARRYING CASE
ACCESSORY COMPONENTS AND QUANTITYTYPE10000A X 10 PASSIVE ATTENUATOR PROBES 3.5 FT LG 2,INSTRUCTION MANUAL 1,POWER CORD 1 AND 3-2 ADAPTER 1
SPECIAL FEATURESPORTABLE; SOLID STATE; OPERATING TEMP 0-55 DEG C; 2 VERTICAL CHANNELS PRODUCING 1 TRACE EACH CHANNEL EQUALS TWO TRACES; FREQ RANGE DC TO 50 MHZ; 5 MV PER CM SENSITIVITY; 7 NS RISE TIME
REFERENCE DATA AND LITERATURETO 33A1-13-458-1