6625-00-148-8097 A test instrument which is designed to give visual indications on an LCD display or a cathode ray tube of instantaneous values and variations in electrical voltage. It can also be used to indicate any quantity which can be converted into terms of electrical potential. It may include an integral pulse generator, the output of which can be used to trigger an external component; be triggered by pulses from an external source, or it may utilize an LCD display or a special type of multigun cathode ray tube and circuitry which permits a trace(s) to be sustained and displayed indefinitely, and the trace(s) may be erased when desired. For items which are not separable and operable when detached from equipment of which they are a part (built into operational equipment), see INDICATOR (2) (as modified); MONITOR (as modified); and RECORDER (as modified). See also OSCILLOGRAPH.
Alternate Parts: 1062M0D116, 6625-00-148-8097, 00-148-8097, 6625001488097, 001488097
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | MAY 28, 1973 | 00-148-8097 | 00357 ( OSCILLOSCOPE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-00-148-8097
Part Number | Cage Code | Manufacturer |
---|---|---|
1062M0D116 | 30669 | E AND R ELECTRONICS INCDBA DUMONT OSCILLOSCOPE |
Technical Data | NSN 6625-00-148-8097
Characteristic | Specifications |
---|---|
SCREEN SIZE | 8 BY 10 CENTIMETERS |
BEAM QUANTITY | 1 |
SWEEP CIRCUITS | INCLUDED |
GENERATOR DRIVEN FEATURE | INCLUDED |
SWEEP CIRCUIT TYPE | D ANY ACCEPTABLE AND F ANY ACCEPTABLE |
SWEEP FREQUENCY RANGE | +0.0 TO +4.0 HERTZ AND +0.0 TO +60.0 MEGAHERTZ |
SINGLE TRIGGER SWEEP DURATION | 0.1 MICROSECONDS MINIMUM AND 1.0 MICROSECONDS MAXIMUM |
AMPLIFIER DEFLECTION SENSITIVITY PROVISION | NOT PROVIDED |
INPUT INTENSITY MODULATION FEATURE | NOT PROVIDED |
AMPLITUDE CALIBRATING VOLTAGE WAVEFORM | SQUARE WAVE |
CALIBRATING PEAK TO PEAK AMPLITUDE | 1.0 VOLTS MINIMUM AND 3.0 VOLTS MAXIMUM |
ACCURACY RANGE IN PERCENT | M1.0/P1.0 |
CAMERA RECORDING DEVICE ACCOMMODATION | NOT PROVIDED |
CURRENT TYPE | AC |
VOLTAGE RATING | 115.0 VOLTS NOMINAL AND 230.0 VOLTS NOMINAL |
FREQUENCY RATING | 48.0 HERTZ NOMINAL AND 400.0 HERTZ NOMINAL |
PHASE | A$B |
OVERALL LENGTH | 21.219 INCHES NOMINAL |
OVERALL WIDTH | 8.250 INCHES NOMINAL |
OVERALL HEIGHT | 11.500 INCHES NOMINAL |
MOUNTING METHOD | CARRYING CASE |
ACCESSORY COMPONENTS AND QUANTITY | TYPE10000A X 10 PASSIVE ATTENUATOR PROBES 3.5 FT LG 2,INSTRUCTION MANUAL 1,POWER CORD 1 AND 3-2 ADAPTER 1 |
SPECIAL FEATURES | PORTABLE; SOLID STATE; OPERATING TEMP 0-55 DEG C; 2 VERTICAL CHANNELS PRODUCING 1 TRACE EACH CHANNEL EQUALS TWO TRACES; FREQ RANGE DC TO 50 MHZ; 5 MV PER CM SENSITIVITY; 7 NS RISE TIME |
REFERENCE DATA AND LITERATURE | TO 33A1-13-458-1 |