NSN 6625-00-173-4977
Part Details | FAULT LOCATING INDICATOR
6625-00-173-4977 An electrically activated item specifically designed to indicate the occurrence of a malfunction in a component of an electronic set, central or system. It may indicate the malfunction by a pop-out button (e.g. ground fault interrupt outlets) or color change by emitted light or displayed in a window. The indicator may utilize a "push to test" button. It does not make quantitative or qualitative tests such a provided by test sets.
Alternate Parts: A21643, 428C264001023, 428C2640-01-023, 4210049001, 421-004-9001, 295200002402, 295-200-0024-02, M161S28, M161S28BW, M161S-28-B/W, MI61S28WB, MI61S28, MI61S-28, A21643, 6625-00-173-4977, 00-173-4977, 6625001734977, 001734977
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | AUG 27, 1972 | 00-173-4977 | 60639 ( INDICATOR, FAULT LOCATING ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-00-173-4977
Part Number | Cage Code | Manufacturer |
---|---|---|
A21643 | 1XP56 | AI-TEK INSTRUMENTS, LLC |
428C2640-01-023 | 86360 | GE AVIATION SYSTEMS LLCDBA GE AVIATION DIV INFORMATION |
421-004-9001 | 64547 | HONEYWELL INTERNATIONAL INCDBA HONEYWELL |
295-200-0024-02 | 58880 | MEGGITT (NEW HAMPSHIRE), INC |
M161S28 | 07479 | MINELCO INCSUB OF TALLEY INDUSTRIES INC |
M161S-28-B/W | 07479 | MINELCO INCSUB OF TALLEY INDUSTRIES INC |
MI61S28WB | 07479 | MINELCO INCSUB OF TALLEY INDUSTRIES INC |
MI61S-28 | 07479 | MINELCO INCSUB OF TALLEY INDUSTRIES INC |
A21643 | 82227 | VDO CONTROL SYSTEMS INC |
Technical Data | NSN 6625-00-173-4977
Characteristic | Specifications |
---|---|
ELECTRICAL CONNECTION QUANTITY | 2 |
PRESENTATION TYPE | WINDOW |
CURRENT TYPE | DC |
DC VOLTAGE RATING | 28.0 VOLTS NOMINAL |
COIL DC RESISTANCE | 800.0 OHMS NOMINAL |
MOUNTING FACILITY TYPE AND QUANTITY | 1 BUSHING |
LENGTH | 0.840 INCHES NOMINAL |
DIAMETER | 0.750 INCHES NOMINAL |
SPECIAL FEATURES | WEAPON SYSTEM ESSENTIAL |
SPECIFICATION/STANDARD DATA | 64547-421-004-9001 MANUFACTURERS SPECIFICATION CONTROL |
CRITICALITY CODE JUSTIFICATION | FEAT |
END ITEM IDENTIFICATION | 26F; 11F; JFN; 10N |