NSN 6625-00-488-4089

Part Details | INSULATION BREAKDOWN TEST SET

6625-00-488-4089 A test set primarily designed to detect and indicate insulation breakdown in electric motors, transformers, and the like, at specific test voltages. See also TEST SET, ARMATURE; and OHMMETER.

Alternate Parts: 203, 6625-00-488-4089, 00-488-4089, 6625004884089, 004884089

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JUN 11, 196900-488-408916408 ( TEST SET, INSULATION BREAKDOWN )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-00-488-4089
Part Number Cage Code Manufacturer
20327746BNF MFG CORP
Technical Data | NSN 6625-00-488-4089
Characteristic Specifications
OUTPUT CURRENT TYPE DC
OUTPUT VOLTAGE RATING2.500 KILOVOLTS NOMINAL
VOLT-AMPERE RATING3.750
INSTALLATION DESIGN PORTABLE
LEAKAGE INDICATOR TYPE LAMP
METER QUANTITYA1$$A1
METER TYPE AMMETER AND VOLTMETER
SCALE RANGE+0.0 TO +1.5 MILLIAMPS AND +0.0 TO +2500.0 VOLTS
AC VOLTAGE RATING110.0 VOLTS NOMINAL
FREQUENCY RATING60.000 HERTZ NOMINAL
PHASE SINGLE
OVERALL LENGTH19.000 INCHES NOMINAL
OVERALL WIDTH7.000 INCHES NOMINAL
OVERALL HEIGHT7.250 INCHES NOMINAL