NSN 6625-00-509-9826

Part Details | WAVEMETER

6625-00-509-9826 An item for the determination of the electrical wavelength or frequency being generated by an electronic equipment such as a radio transmitter. It may be placed in the radiation field of the equipment, thereby operating on the "absorption" principle, or connected into a transmission line or waveguide run between the equipment and a component such as an antenna, thereby operating on the tuned cavity resonance principle. It includes inscriptions from which the wavelength or frequency can be determined directly, or by reference to an associated calibration curve or tabulation. the wavemeter operates in accordance with its design function only when the equipment under measurement is operating. For items, such as grid dip meters, that determine the same information when the equipment under measurement is not operating, see FREQUENCY METER.

Alternate Parts: ANUPM2, 6625-00-509-9826, 00-509-9826, 6625005099826, 005099826

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66JAN 01, 196100-509-982600783 ( WAVEMETER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6625-00-509-9826
Part Number Cage Code Manufacturer
ANUPM280058JOINT ELECTRONICS TYPE DESIGNATIONSYSTEM
Technical Data | NSN 6625-00-509-9826
Characteristic Specifications
INSTRUMENT CALIBRATION RANGE80 TO 1220 MC RANGE
CALIBRATION ACCURACY RATINGPORM 1 PCT ACCURACY
INDICATOR TYPEJJ ANY ACCEPTABLE
OPERATING RANGE-0.1 TO +1.0 MILLIAMPERES
RECTIFIER TYPE 1N21 CRYSTAL
INTERNAL BATTERY ACCOMMODATION NOT INCLUDED
OVERALL LENGTH13.688 INCHES NOMINAL
OVERALL WIDTH8.750 INCHES NOMINAL
OVERALL HEIGHT5.625 INCHES NOMINAL
ACCESSORY COMPONENTS AND QUANTITY1 SPARE CRYSTAL
CASE MATERIAL STEEL
CASE SURFACE TREATMENT FINISH, CRACKLE