NSN 6680-01-167-2132
Part Details | DIFFERENTIAL PRESSURE FLUID FLOW INDICATING METER
6680-01-167-2132 An instrument designed to measure the rate of flow of a fluid through a pipeline, based on the exact relation which differential pressure bears to fluid velocity, and this measurement indicated on a graduated scale by a pointer directly connected to a mercury or oil sealed bell or a bellows. It may or may not have a totalizing integrator register built in. Excludes: METER, FLOW RATE INDICATING; METER, FLUID FLOW INDICATING, ELECTROMAGNETIC; and METER, FLUID FLOW INDICATING, ULTRASONIC.
Alternate Parts: 145C403N01, 171VDR30CDF, 1-71VDR30CDF, 6680-01-167-2132, 01-167-2132, 6680011672132, 011672132
| Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
|---|---|---|---|
| 66 | NOV 23, 1983 | 01-167-2132 | 08249 ( METER, FLUID FLOW INDICATING, DIFFERENTIAL PRESSURE ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6680-01-167-2132
| Part Number | Cage Code | Manufacturer |
|---|---|---|
| 145C403N01 | 97942 | NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NORTHROP GRUMMAN SYSTEMS |
| 1-71VDR30CDF | 54135 | RCM INDUSTRIES INC |
Technical Data | NSN 6680-01-167-2132
| Characteristic | Specifications |
|---|---|
| MEDIA FOR WHICH DESIGNED | NONFREEZING LIQUID |
| MAXIMUM DIFFERENTIAL PRESSURE | NOT RATED |
| CAPACITY RATING | 30.0 GALLON PER MINUTE |
| SCALE PRESENTATION RANGE | 0 TO 30 NUMERICAL RANGE |
| SMALLEST INCREMENT INDICATED | 4.000 |
| SCALE INSCRIPTION/BACKGROUND COLOR | BLACK MARKINGS OVER WHITE BACKGROUND |
| TOTALIZING INTEGRATOR REGISTER | NOT INCLUDED |
| CASE MATERIAL | ALUMINUM ALLOY |
| CASE SHAPE | RECTANGULAR |
| DEPTH | 2.750 INCHES NOMINAL |
| HEIGHT | 4.000 INCHES NOMINAL |
| WIDTH | 4.000 INCHES NOMINAL |
| INLET CONNECTION SIZE | 1.000 IN. PIPE THD. |
| OUTLET CONNECTION SIZE | 1.000 IN. PIPE THD. |
| END ITEM IDENTIFICATION | COOLANT MANIFOLD ON FAA AIR ROUTE SURVEILLANCE RADAR MODEL ARSR-3 |