NSN 6685-00-270-3276
Part Details | INDICATING TEMPERATURE CONTROL
6685-00-270-3276 A device composed of one or more control-actuating mechanisms, one or more switchs, and graduated scales or other indicators. It is designed to measure and control temperature in ovens, furnaces, and the like, through perception of a sensing element connected to the control. Excludes SWITCH, THERMOSTATIC(00451) and THERMOSTAT, FLOW CONTROL(16516).
Alternate Parts: JP2035, 442AT02X, 6685-00-270-3276, 00-270-3276, 6685002703276, 002703276
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | JAN 01, 1963 | 00-270-3276 | 05662 ( CONTROL, TEMPERATURE, INDICATING ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-00-270-3276
Part Number | Cage Code | Manufacturer |
---|---|---|
JP2035 | 29215 | JENNY PRODUCTS, INC. |
442AT02X | 92578 | JOHNSON CONTROLS INCCONTROL PRODUCTS DIV |
Technical Data | NSN 6685-00-270-3276
Characteristic | Specifications |
---|---|
POWER SOURCE | EXTERNAL |
INTELLIGENCE DATA HANDLING CAPABILITY | AABD TEMPERATURE RECEIVING |
INDICATION METHOD | TRANSMITTING CONCENTRIC SCALE |
CASE MATERIAL | STEEL |
CASE SURFACE TREATMENT | ENAMEL |
INCLOSURE TYPE | ENCASED |
MAXIMUM OVERALL LENGTH | 4.000 INCHES |
MAXIMUM OVERALL WIDTH | 3.188 INCHES |
MAXIMUM OVERALL HEIGHT | 2.062 INCHES |
SENSING ELEMENT TYPE AND LOCATION | CAPILLARY TUBE REMOTE |
OPERATING TEMP RANGE | +100.0 TO +450.0 DEG FAHRENHEIT |
MOUNTING METHOD | SURFACE |