NSN 6685-00-276-1308
Part Details | PSYCHROMETER
6685-00-276-1308 An instrument that senses, measures, and indicates the amount of relative humidity in the atmosphere. It consists of two liquid-in-glass thermometers, one of which is equipped with a wick. Air movement (aspiration) is effected by slinging the instrument about, by use of blower, fan or the like; or the instrument may be used with no forced circulation of air.
Alternate Parts: 1330, 23040, 6685-00-276-1308, 00-276-1308, 6685002761308, 002761308
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
66 | JAN 01, 1963 | 00-276-1308 | 09725 ( PSYCHROMETER ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6685-00-276-1308
Part Number | Cage Code | Manufacturer |
---|---|---|
1330 | 59310 | ABB KENT-TAYLOR INC |
23040 | 26659 | H-B INSTRUMENT CO |
Technical Data | NSN 6685-00-276-1308
Characteristic | Specifications |
---|---|
CIRCULATION TYPE | FORCED |
CIRCULATION METHOD | J ANY ACCEPTABLE |
THERMOMETER QUANTITY | 2 |
OPERATING TEMP RANGE | +10.0 TO +110.0 DEG FAHRENHEIT |
GRADUATION INTERVAL | 0.5 DEG |
CALIBRATION ACCURACY RATING | PORM 0.5 DEG FROM EITHER SIDE OF RANGE,DEG F |
ENGRAVED THERMOMETER STEM | INCLUDED |
MAGNIFYING LENS | NOT INCLUDED |
THERMOMETER FILLING TYPE | MERCURY |
OVERALL LENGTH | 10.750 INCHES NOMINAL |
OVERALL WIDTH | 1.375 INCHES NOMINAL |
OVERALL HEIGHT | 0.438 INCHES NOMINAL |
THERMOMETER MOUNTING METHOD | FW ANY ACCEPTABLE |
THERMOMETER MOUNTING MATERIAL | ALUMINUM |
THERMOMETER MOUNTING SURFACE TREATMENT | ANY ACCEPTABLE |
CISTERN MATERIAL | ANY ACCEPTABLE |
SLING HANDLE | INCLUDED |
HANDLE TYPE | SWIVEL |
CARRYING CASE MATERIAL | LEATHER |
MOUNTING SHELTER | NOT INCLUDED |
MOUNTING PANEL TABLES | NOT PROVIDED |
ACCESSORY COMPONENTS AND QUANTITY | BOTTLE W/DROPPER 1,US WEATHER BUREAU PSYCHROMETRIC TABLES NO. 235 1,WICKING 1 |
END ITEM IDENTIFICATION | COMBAT SYTEM SUPPORT EQUIP.; ANTI-SUB SYTSTEMS |