NSN 6695-01-505-6482

Part Details | FLUID-HYDRAULIC PRESSURE TRANSDUCER

6695-01-505-6482 An instrument that senses, measures and converts pressure of a hydraulic fluid into electrical signals. The item contains at least one (1) input pressure port and one (1) electrical output connection. The instrument may measure absolute, differential or gage pressure. The sensor may be of the piezoresistive diaphragm, diaphragm with semiconductor strain gage, or foil strain gage construction. Electrical output may be direct or alternating current.

Alternate Parts: 724920, 2133667001, 213-36-670-01, 21336670, 213-36-670, BMEXX1105000A, BME-XX-110-5000A, 6695-01-505-6482, 01-505-6482, 6695015056482, 015056482

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
66MAR 12, 200301-505-648252029 ( TRANSDUCER, PRESSURE, FLUID-HYDRAULIC )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 6695-01-505-6482
Part Number Cage Code Manufacturer
72492053711NAVAL SEA SYSTEMS COMMAND
213-36-670-0113624ROSEMOUNT SPECIALTY PRODUCTS LLCDIV EMERSON ELECTRIC CO.
213-36-67013624ROSEMOUNT SPECIALTY PRODUCTS LLCDIV EMERSON ELECTRIC CO.
BME-XX-110-5000A37345SOUPES CAMPBELL LTEE LES DIVGATTUSO-HABITANT
Technical Data | NSN 6695-01-505-6482
Characteristic Specifications
VOLTAGE RATING10.0 VOLTS NOMINAL
ELECTRICAL CONNECTION QUANTITY1
TERMINAL QUANTITY4
TERMINAL TYPE CONNECTOR, RECEPTACLE
MEASUREMENT RANGE+0.0 TO +5000.0 POUNDS PER SQUARE INCH ABSOLUTE
OVERALL LENGTH3.300 INCHES NOMINAL
OVERALL WIDTH1.050 INCHES MAXIMUM
SPECIAL FEATURESINPUT VOLTAGE: +20.0 TO +28.0VDC;INPUT CURRENT: 50MA MAXIMUM;COMPENSATED TEMPERATURE RANGE: MINUS 20 DEGREES FAHREINHEIT TO 122 DEGREES FAHREINHEIT;(DRAWING)TRANSDUCER,PRESSURE(213-36-670)
END ITEM IDENTIFICATIONMK32 MOD2,SLIDE,5/62 CAL GUN